Calculation Of Air Volume Of Reverse Hanging Film In Sewage Tank

For different types of sewage tanks, the design schemes of the anti-hanging membrane structure​ used, the membrane materials used, and the treatment process are different. During the use of the anti-hanging film cap, its calculation of the inlet and outlet air volume will be different.

Get Started >

For different types of sewage tanks, the design schemes of the anti-hanging membrane structure used, the membrane materials used, and the treatment process are different. During the use of the anti-hanging film cap, its calculation of the inlet and outlet air volume will be different. The number of air changes during operation of the operating space is also different. The following editor will explain the difference in air volume calculation with the cover of the grit tank, the cover of the sludge thickening tank, and the cover of the membrane structure of the deodorizing biochemical tank:

1. Reverse hanging film cover for grit tank: mainly the odor caused by lack of oxygen. Generally, the structure or equipment is covered separately. For the space that does not enter the operation, the number of air changes is 2-3 times. For the space that enters the operation, change The gas frequency is 5-8 times, which is not suitable for industrial wastewater with volatile components.

2. The sludge thickening tank is covered to deodorize: it is one of the most important odor sources in the sewage plant. Since most of the sludge thickening tanks have thickening and scraping equipment, try to use lower cover without affecting the operation For collection, the number of air changes is 3-5 times. The dehydration system generally collects sludge separately.

3. The membrane structure of the biochemical pool : for the anoxic part, it is not considered for operation, and the number of air changes is 2-3. For the aerobic part, it is not recommended to collect without special requirements. If it must be collected, follow the exposure The air volume is added to the air volume of the collection space approximately once.

  • ENVIRONMENTAL FACILITIES

  • COMMERCIAL FACILITIES

  • AIR DOME STRUCTURES

  • TRANSPORTATION AND TRAFFIC FAC

  • ATHLETIC AND SPORTS FACILITIES

  • LANDSCAPE AND SHADE STRUCTURES

Calculation Of Air Volume Of Reverse Hanging Film In Sewage Tank

What risks can be avoided by covering the sewage tank with anti hanging membrane?

The usage rate of reverse hanging membrane covering in sewage tanks is increasing now. So, what risks can reverse hanging membrane covering in sewage tanks avoid? Let's take a closer look together.

Choose air film building to see which advantages?

With the progress of science and technology and the popularity of the concept of environmental protection, gas film building, as an innovative form of building, is gradually favored by people.So, when choosing a gas film building, what advantages should we pay attention to?

Where is the difficulty of VOCs pollution control?

In recent years, ozone pollution has become a difficult problem affecting the improvement of atmospheric environment quality. As one of the main precursors of ozone formation, VOCs pollution control is an important topic for the "14th Five-Year Plan" PM2.5 and ozone collaborative control. Where is the difficulty of VOCs pollution control?

Transform the football field, the characteristics of the gas membrane indoor football field

Inflatable membrane football stadium belongs to the indoor football field, the main structure adopts membrane structure design, the principle is the same as that of large balloons, due to the difference in internal and external pressure of the membrane structure, the tens of tons of membrane structure expands, and the surrounding is connected with the ground and anchored by steel cables and concrete ground, forming a tight air support structure, which can be built in the shortest time.

From the Learning Center